The Glaciator X-Stream creates a total, ground fog effect from a self-contained unit. The Glaciator X-Stream utilizes the simple but effective Jem heavy fog fluids and a closed loop refrigeration system for a heavy fog solution.
|
| Features |
- Density control: low, medium or high
- Continuous output
- 80 m2/min fog output
- 3500 W heat exchanger
- 15 min heat-up time
- 5 liter fluid capacity
- Different fluid options for different applications
- Internal or external fluid supply
- Low fluid sensing
- Self contained unit: no C02 or dry ice
- Onboard DMX
- On-board control panel
- Optional ducting system
|
Physical |
| Length: 866 mm (34.1 in.) |
| Width: 638 mm (25.1 in.) |
| Height: 725 mm (28.5 in.) |
| Dry weight: 110 kg (242.5 lbs.) |
Performance |
| Coverage volume: 80 m2 per minute |
| Operating time: Continuous, automatic level adjustment |
| Warm-up time (approx.): 15 minutes |
Control and Programming |
| Control options: Onboard control panel, DMX |
| Compatible remote controls: For limited control |
| DMX channels: 2 (output and compressor) |
| Protocol: USITT DMX512/1990 |
Construction |
| Housing: Steel & aluminum |
| Heat exchanger: 3500 W, direct thermal protection |
Fluid System |
| Fluid pump: Oscillating piston, high pressure X2 |
| Onboard fluid capacity: Internal 5 l reservoir |
| External fluid supply: For larger volume remote fluid supply |
| Fluid consumption at peak output: 120 ml per minute |
Installation |
| Orientation: Floor mount only (On wheels) |
Connections |
| Remote control: 3-pin locking XLR |
| DMX data: 3-pin locking XLR |
| Power cable entry: IEC-EN60309-2 Socket (Cee Type) |
Electrical |
| AC power (EU models): 220-240 V nominal, 50 Hz |
| Main fuse (220-240 V power): Onboard 32 A Breaker |
| AC power (US models): 208 V, 60 Hz |
| Main Fuse (208 V power): Onboard 32 A Breaker |
Typical Power and Current |
| 220 V, 50 Hz: 4483 W, 20.3 A |
| 230 V, 50 Hz: 4900 W, 21.3 A |
| 240 V, 50 Hz: 5335 W, 22.23 A |
| Measurements made at nominal voltage. Allow for a deviation of +/- 10%. |
| 208 V, 60 Hz: 4200 W, 22.5 A |
| Measurements made at nominal voltage. Allow for a deviation of +/- 10%. |
Thermal |
| Maximum ambient temperature (Ta max.): 40° C (104° F) |
| Exterior surface temperature, steady state: 50° C (122° F) |
| Max. nozzle temperature: 200° C (392° F) |
Approvals |
| |
| EU safety: EN 50 081-1, EN 50 082-1 |
| EU safety: EN 60 335-1 (1995) |
Included Items |
|
| 'C' form female socket for use with own power cable | P/N 05327240 |
|
| Container 5 l | P/N 34300506 |
|
Accessories |
|
|
| JEM Multi-function (Analog) Remote Control | P/N 92765013 |
|
| Ducting Kit incl. twin adapter and 2 x 5 m (16.4 ft.) ducting | P/N 92625007 |
|
Ordering Information |
| Jem Glaciator X-Stream, 240 V | P/N 92210500 |
|
| Jem Glaciator X-Stream, 208 V | P/N 92210501 |
|
| |